Add to Cart
H03VVH2-F PVC Electrical Cable Twin Flat Flexible Cable for General Use
APPLICATION
Manufactured in accordance with European harmonised code (HAR standard cables) H03VVH2-F, This range of PVC cable is suitable for use as a general supply lead, for pendant lighting drops and for light portable domestic appliances. However, it is not suitable for heating and cooking appliances.
CABLE STANDARDS
BS EN 50525-2-11 (previously BS 6500),
BS EN/IEC 60332-1-2
DIMENSIONS
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL THICKNESS OF INSULATION mm | NOMINAL THICKNESS OF SHEATH mm | NOMINAL OVERALL DIAMETER H x W mm | NOMINAL WEIGHT kg/km |
2 | 0.5 | 0.5 | 0.6 | 3.35 x 5 | 30 |
2 | 0.75 | 0.5 | 0.6 | 3.5 x 5.5 | 37 |
CONDUCTORS
Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables
NOMINAL CROSS SECTIONAL AREA mm² | MAXIMUM DIAMETER OF WIRES IN CONDUCTOR mm | MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC | |
Plain Wires ohms/km | Metal-Coated Wires ohms/km | ||
0.5 | 0.21 | 39 | 40.1 |
0.75 | 0.21 | 26 | 26.7 |
ELECTRICAL CHARACTERISTICS
Current Carrying Capacity and Mass Supportable
NOMINAL CROSS SECTIONAL AREA mm² | CURRENT CARRYING CAPACITY | MAXIMUM MASS SUPPORTABLE BY TWIN FLEXIBLE CORD kg | |
Single-Phase AC Amps | Three-Phase AC Amps | ||
0.5 | 3 | 3 | 2 |
0.75 | 6 | 6 | 3 |
Voltage Drop
NOMINAL CROSS SECTIONAL AREA mm² | DC OR SINGLE-PHASE AC mV/A/m | THREE-PHASE AC mV/A/m |
0.5 | 93 | 80 |
0.75 | 62 | 54 |
DE-RATING FACTORS
AIR TEMPERATURE | 35ºC | 40ºC | 45ºC | 50ºC | 55ºC |
DE-RATING FACTOR | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |