Add to Cart
AAAC Conductor All Aluminium Alloy Overhead Power Transmission Line
APPLICATION
AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC/ACSR.
CABLE STANDARDS
ASTM - B 399 Metric Units, ASTM - B 231, TS IEC 1089,
DIN 48201, BS 215, UNE 21.018
DIMENSIONS
American Standard All Aluminum Alloy 6201-T81 Conductors ( AAAC ) |
||||||||||
Code Name |
Total Area | 1350 Grade Equivalent (Approx) |
Stranding | Conductor Nominal Diameter |
Nominal Weight |
Rated Strength |
Maximum DC resistance at 20 ℃ |
|||
AWG or MCM |
mm2 | AWG or MCM | No/ mm | mm | kg/km | kN | Ω /km | |||
Akron | 30.58 | 15.52 | 6 | 7 | x | 1.68 | 5.04 | 43 | 4.92 | 2.1588 |
Alton | 48.69 | 24.71 | 4 | 7 | x | 2.12 | 6.36 | 68 | 7.83 | 1.3557 |
Ames | 77.47 | 39.19 | 2 | 7 | x | 2.67 | 8.01 | 108 | 12.42 | 0.8547 |
Azusa | 123.3 | 62.44 | 1 | 7 | x | 3.37 | 10.11 | 171 | 18.88 | 0.5365 |
Anaheim | 155.4 | 78.55 | 2/0 | 7 | x | 3.78 | 11.34 | 216 | 23.75 | 0.4264 |
Amherst | 195.7 | 99.3 | 3/0 | 7 | x | 4.25 | 12.75 | 272 | 30.03 | 0.3373 |
Alliance | 246.9 | 125.1 | 4/0 | 7 | x | 4.77 | 14.31 | 343 | 37.83 | 0.2678 |
Butte | 312.8 | 158.6 | 266.8 | 19 | x | 3.26 | 16.3 | 435 | 46.46 | 0.2112 |
Canton | 394.5 | 199.9 | 336.4 | 19 | x | 3.66 | 18.3 | 548 | 58.56 | 0.1676 |
Cairo | 465.4 | 236.4 | 397.5 | 19 | x | 3.98 | 19.9 | 649 | 69.25 | 0.1417 |
Darien | 559.5 | 283.57 | 477 | 19 | x | 4.36 | 21.8 | 778 | 83.1 | 0.1181 |
Elgin | 652.6 | 331 | 556.5 | 19 | x | 4.71 | 23.55 | 908 | 96.98 | 0.1012 |
Flint | 740.8 | 374.5 | 636 | 37 | x | 3.59 | 25.13 | 1028 | 107.36 | 0.0894 |
Greeley | 927.2 | 469.6 | 795 | 37 | x | 4.02 | 28.14 | 1289 | 134.62 | 0.0713 |
ASTM Standard All Aluminum Alloy 6201-T81 Conductors ( AAAC ) |
||||||||||
Code Name |
Total Area | 1350 Grade Equivalent (Approx) |
Stranding | Conductor Nominal Diameter |
Nominal Weight |
Rated Strength |
Maximum DC resistance at 20 ℃ |
|||
AWG or MCM |
mm2 | AWG or MCM | No/ mm | mm | kg/km | kN | Ω /km | |||
6 | 13.28 | 9 | 7 | 7 | / | 1.554 | 4.66 | 36 | 4.206 | 2.523 |
4 | 21.14 | 7 | 11 | 7 | / | 1.961 | 5.88 | 58 | 6.698 | 1.5844 |
2 | 33.65 | 5 | 18 | 7 | / | 2.474 | 7.42 | 92 | 10.66 | 0.9955 |
0 | 53.48 | 3 | 28 | 7 | / | 3.119 | 9.36 | 147 | 16.94 | 0.6263 |
2/0 | 67.46 | 2 | 35 | 7 | / | 3.503 | 10.51 | 185 | 20.4 | 0.4965 |
3/0 | 85 | 1 | 45 | 7 | / | 3.932 | 11.8 | 233 | 25.7 | 0.3941 |
4/0 | 107.3 | 1/0 | 56 | 7 | / | 4.417 | 13.25 | 294 | 32.44 | 0.3123 |
250 | 126.6 | 133 | 66 | 19 | / | 2.913 | 14.57 | 347 | 38.86 | 0.2645 |
300 | 152.1 | 159 | 80 | 19 | / | 3.193 | 15.97 | 417 | 46.69 | 0.2202 |
350 | 177.3 | 186 | 93 | 19 | / | 3.447 | 17.24 | 486 | 51.94 | 0.1889 |
Product Tags:
Power Transmission AAAC Conductor All Aluminium Alloy 6201 - T81 Overhead Line
Inquiry Cart